It’s rare to find good customer service let alone a company that goes above and beyond. My AC unit needed replaced thanks to the R-22 phase out and our overly regulated federal government (need I digress). My father had a great experience with Westin Air a couple years ago so I gave them a call. Cathy provided a quote and promptly answered several email questions. The bid from Westin Air was almost a $1000 better than competitive bids I received for the same unit! My installation requirements were unique and Westin Air went out of their way during a busy season to assist with the solution. The installation process went smooth and the technicians kept the house clean (used drop cloths without being asked to keep the path from the front door to the basement clean). Westin Air provided a trifecta…best product, best price and best service. I proudly recommend Westin Air.
Seth has done a tremendous job helping us out with ac and heating issues. He's fast, friendly, knowledgeable and trustworthy. Highly recommend Westin air. The entire staff has been great, making difficult times easier.
We've worked with Westin Air for years and couldn't ask for a better group of guys to help. They are knowledgeable and timely in their work.
Inspected furnace and cleaned control board removing dirt and dust buildup. Reinstalled bracket to secure 14x25x1 filter into the bottom of the furnace as designed to keep dirt trapped outside of unit. Performed heating maintenance verifying heat operation and component operations.
Checked and found bad hot surface ignitor replaced ignitor with oem 767a- 370 ignitor cycled furnace 3 times positive ignition all three times furnace operating properly at this time left tstat at 68 degrees
Upon arrival, system was in heating on mode. Inspection of furnace shows the control board is flashing code 24-secondary voltage fuse open. Inspection of control board snd wiring shows no shorts to ground. Inspection of thermostat wiring shows that the Blue wire rhat is hooked to common in the furnace is hooked up to B on thermostst. B on the thermostat is used as a heating changeover valve control. When heating is turned on, B is energized, and in this wiring setup, it is a direct connection from power to ground causing the secondary voltage fuse to blow. Current thermostat that appears to be new does not require a common wire. Removed blue wire from thermostat and furnace control board. Test ran in heating, cooling, and fan only modes with no other issues found. System is operational at this time.
System two North hallway and school entrance office Outdoor unit locked out on Comfort Alert service code 4 - locked rotor amps Discovered bad starting relay contactor and replaced. Cooling test run is an excellent condition at this time. Air filters have already been replaced and system is producing 50.3 supply temperature with 306 & 120 running pressures
Replacing Honeywell Vision Pro 8000 thermostat with faulty touch screen with new Honeywell Vision Pro 8000 in Canal Winchester, OH
Replaced a 90% Furnace in Canal Winchester
Installed a Trane AC and coil in Canal Winchester
Lennox Merit series replacement ignition control board and hot surface ignitor upgrade kit Englecrrest Dr. Canal Winchester, OH 43110
Aprilaire 600m whole house humidifier accessory install Winchester Crossing Blvd Columbus, OH 43110
Trane xr13 Spring cleaning and tune up. Filter rotation and Freon pressure test Winchester Crossing Canal Winchester Ohio
Performing seasonal preventive maintenance for this upcoming spring/summer. Near canal Winchester, Ohio. Furnace repair, HVAC
Lennox pulse 21 gas furnace heat exchanger diagnostics Dayspring Community Church Brice rd. Canal Winchester Ohio 43110
Lennox AC no cool R&R secondary start controller capacitor Install new Reme Halo Englerest Dr Canal Highlands Canal Winchester